ProLoop LOS (300m2)


Discontinued


Discontinued item. Please contact us for information on alternatives.

 
  • ProLoop LOS (300m2)
 
 
 
ProLoop LOS (300m2)
  • Description

    • The PROLOOP LOS is a complete system for the operation of low-overspill systems. It includes the complete range of electronics required in a single enclosure. Thus, there is a flexibly sized, reliable low-overspill solution available to serve neighbouring event rooms and assembly halls up to 300 square metres in size.

      The system is equipped with Automatic Gain Control (AGC) to produce stable sound with outstanding speech reproduction, even under difficult acoustic conditions. The integrated monitor output for the corresponding measurement technology makes it possible to easily and conveniently test the sound quality of the induction loop system.

      • Uniform coverage throughout the room (no dead spots in the middle of the room)
      • No signal fluctuations when hearing-aid user moves his/her head
      • Reduced sensitivity in respect to architecture-related steel reinforcements
      • High efficiency, low power consumption
      • 19“ design
      • Well suited for retrofitted installation in theatres, cinemas, concert halls, schools, conference rooms, housing, etc. (Possible for floor reconstructions only)
  • Technical Information

    • Mains connection: 230-240 V AC 50 Hz, 25-700 W

      Coverage: 300 m² acc. to IEC 60118-4

      Induction loop output

      Max. power: 2 x 4 A RMS, short-circuit-proof

      Max. voltage: 47 V from peak to peak

      Output AGC

      Sets voltage and power for steady signals like oscillation and sine curves after 0.6-1 seconds to -10 dB. Short pulses and normal program signals are not limited.

      Frequency range: 100 - 5000 Hz ( ± 3 dB)

      Distortion: < 1%

      Cable connection: 2 screw connections on rear panel of the amplifier

      Outputs

      Master OUT: 0 dBm, RCA (with AGC function)

      Slave OUT: 0 dBm, RCA (with AGC function)

      Inputs

      IN 1: 

      Combined XLR / 6.35 mm connector

      MIC sensitivity 2.5 mV – 10V RMS / 10 kOhm,

      LINE sensitivity 37 mV – 10V RMS / 10 kOhm

      or phantom voltage 9 – 20 V

      IN 2:

      Dual RCA connections, 45 mV – 10V RMS / 10kOhm

      IN 3:

      Dual RCA connections, 45 mV – 10V RMS / 10kOhm

      AGC

      Dynamics: > 70 dB

      Rise time: 2 - 500 ms

      Fall time: 0.5 – 20 dB/s Rise and fall times depend on the currently active channel

      Controls and displays

      Loop setting: 0 – 300m² (with one potentiometer each for master and slave outputs)

      Input level: IN 1 and IN 2 can be adjusted separately

      Displays

      Mains connection: 1 green LED

      Input level: 1 green LED

      Induction loop power: 2 green LED

      Induction loop monitoring

      Two 6.3 mm jacks for headphone connection

      Enclosure

      Dimensions (H x W x D): 88 x 438 x 280 mm

      Colour: black

      Weight: 9,3 kg

      • Mains connection: 230-240 V AC 50 Hz, 25-700 W
      • Coverage: 300 m² acc. to IEC 60118
      • Induction loop output
      • Max. power: 2 x 4 A RMS, short-circuit-proof
      • Max. voltage: 47 V from peak to peak
      • Output AGC
      • Sets voltage and power for steady signals like oscillation and sine curves after 0.6-1 seconds to -10 dB. Short pulses and normal program signals are not limited.
      • Frequency range: 100 - 5000 Hz ( ± 3 dB)
      • Distortion: < 1%
      • Cable connection: 2 screw connections on rear panel of the amplifier
      • Outputs
      • Master OUT: 0 dBm, RCA (with AGC function)
      • Slave OUT: 0 dBm, RCA (with AGC function)
      • Inputs
      • IN 1: 
      • Combined XLR / 6.35 mm connector
      • MIC sensitivity 2.5 mV – 10V RMS / 10 kOhm,
      • LINE sensitivity 37 mV – 10V RMS / 10 kOhm
      • or phantom voltage 9 – 20 V
      • IN 2:
      • Dual RCA connections, 45 mV – 10V RMS / 10kOhm
      • IN 3:
      • Dual RCA connections, 45 mV – 10V RMS / 10kOhm
      • AGC
      • Dynamics: > 70 dB
      • Rise time: 2 - 500 ms
      • Fall time: 0.5 – 20 dB/s Rise and fall times depend on the currently active channel
      • Controls and displays
      • Loop setting: 0 – 300m² (with one potentiometer each for master and slave outputs)
      • Input level: IN 1 and IN 2 can be adjusted separately
      • Displays
      • Mains connection: 1 green LED
      • Input level: 1 green LED
      • Induction loop power: 2 green LED
      • Induction loop monitoring
      • Two 6.3 mm jacks for headphone connection
      • Enclosure
      • Dimensions (H x W x D): 88 x 438 x 280 mm
      • Colour: black
      • Weight: 9,3 kg

Product Questions

You may also like...

LA90 Handset Kit
LA90 Handset Kit

From £32.49